The standards have lugs at 500mm centres to enable ledgers to
be attached where required. Each standard takes a load of four
tons with ledgers placed in 4 directions at a maximum of 1.5m
centres and can be joined by a connector.
High Tensile Tube:
48mm Diameter
| Length (mm) |
Mass (kg) |
4 000
3 500
3 000
2 500
2 000
1 500
1 000
500 |
20.5
17.9
14.8
12.3
9.8
7.4
4.9
2.5 |
NOTE: Maximum safe sheer load on each "V" pressing is
10kN.